Potter PFC-5004E 4 Zone Expandable Fire Control Panel
Potter's PFC-5004E Fire Alarm Control Panel is a microprocessor
based unit designed for small to medium commercial, residential, multifamily,
institutional and industrial occupancies. Fully configurable
using DIP switches, it enables the user to configure the system to meet
their specific requirements.
The PFC-5004E comes standard with 4 Class B (Style B) Initiating
Circuits which may be configured as 2 Class A (Style D) circuits. In
addition, it comes equipped with 2 Class A/B (Style Z/Y) Indicating
circuits which are each rated at 1.7 amps. The PFC-5004E can be
expanded up to 8 Class B (Style B) or 4 Class A (Style D) Initiating
Circuits and 4 Class A/B (Style Z/Y) Indicating circuits with the addition
of a ZA-42 Adder Circuit Module. The panel also INCLUDES A 5 Amp
Power Supply which powers the system and supplies a 4-wire resettable
regulated smoke power supply of 24 VDC 100mA maximum.
The PFC-5004E utilizes a simple DIP switch configuration for programming initiating and indicating circuits as well as the enabling and disabling of system functions such as Signal Silence, Fire Drill and Auxiliary Disconnect. Some predefined initiating circuits can optionally be configured Waterflow or Latching/Non-Latching Supervisory. In addition, the PFC-5004E allows for Alarm Verification on the initiating Stock No. 3992020 S735 Product includes a 5 year warranty 7165-0328: 0155 circuits. The indicating circuits may be configured as Silenceable or Non-Silenceable with the audibles configured for Steady, March-Time, Temporal Code, or California Code. Sync module required for strobe synchronization.
The PFC-5004E is equipped with auxiliary relay contacts for Common Alarm, Trouble and Supervisory. If no Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay. The cabinet is available in a beige color for the Canadian market and a red exterior for the U.S. and International markets.
Manufacturer Part Number | PFC-5004E |
---|---|
Features | 4 Class B (Style B) with 2 Class A (Style D) Initiating Circuits.
Expandable up to 8 Class B (Style B) 4 Class A (Style D) Initiating Circuits. • Predefined Initiating Circuits can be configured as Waterflow or Latching/Non- Latching Supervisory • Selectable Alarm Verification on Initiating Circuits • Zone Disconnect Switches • 5 Amp Power Supply • 2 Class A/B (Style Z/Y) Notification Circuits (1.7 Amps max. per circuit.) Expandable up to 4 Class A/B (Style Z/Y) Notification circuits. • Each Notification Circuit can be configured as Silenceable or Non-Silenceable. • Audibles may be configured as Steady, Temporal Code, California Code, or March Time. • Auto Signal Silence • Auxiliary relay contacts for Common Alarm, Common Trouble, and Common Supervisory. • Built-in RS-485 Interface for RA8F Multiplexed Remote Annunciators (Up to 3 Annunciators) • Built-in Walk Test operation • Output for 4-wire resettable regulated smoke power supply • Easy configuration via DIP switches |
Expandable up to 8 Class B (Style B) 4 Class A (Style D)
Initiating Circuits.
• Predefined Initiating Circuits can be configured as Waterflow or
Latching/Non- Latching Supervisory
• Selectable Alarm Verification on Initiating Circuits
• Zone Disconnect Switches
• 5 Amp Power Supply
• 2 Class A/B (Style Z/Y) Notification Circuits (1.7 Amps max. per
circuit.) Expandable up to 4 Class A/B (Style Z/Y) Notification
circuits.
• Each Notification Circuit can be configured as Silenceable or
Non-Silenceable.
• Audibles may be configured as Steady, Temporal Code, California
Code, or March Time.
• Auto Signal Silence
• Auxiliary relay contacts for Common Alarm, Common Trouble,
and Common Supervisory.
• Built-in RS-485 Interface for RA8F Multiplexed Remote
Annunciators (Up to 3 Annunciators)
• Built-in Walk Test operation
• Output for 4-wire resettable regulated smoke power supply
• Easy configuration via DIP switches